Pearson logo Pearson logo

Refrigeration

E-Z Kold - icebox conversion

  • Model EK-12CPA
    • Installed Sept 2007
    • Uses R124a refrigerant
    • Lines have quick-connect/quick-disconnect pressurized fittings
    • Utilizes "spillover" design. Using 1" foam, icebox is divided into 1/3 freezer - 2/3 refrigerator sections, with a 3" spillover between them.
  • Cold Plate:
    • Welded stainless
    • Size 16" x 10" x 2.5"
    • Uses glycol/water eutectic solution
    • Freezing point -25°C
  • Condensing Unit:
    • Air cooled
    • Mounted in upper-aft end of port cockpit locker, behind perf-board shield
    • Uses Danfoss BD 3.5 compressor
      • Brushless 12VDC motor
      • Rated for continuous operation at 45 degrees of heel
      • Rated current while running: 6 Amps
      • Measured current draw: 6.6A
      • Average runtime 4-6 hrs per day
      • Average power consumption 33 Amp-Hours per day, after initial cooldown
      • Directly wired to #2 battery, bypassing main battery switch
      • Toggle switch with in-line ____A fuse, mounted thru port bulkhead, above icebox
  • Digital Thermostat
    • Model MT-511Ril from Full Gauge Controls
    • Mounted in port side of trim panel under companionway
    • Requires 72mm x 29 mm cutout
    • NO contact rated at 8 Amps
    • Control range: -50 - 105°C / -58 - 221°F
    • Settable hystersis: default -15°C off / -10°C on
    • Selectable C/F display